Skip to content
BPindex — The Largest Building Products Directory in the UK

FUSION electric water heating

Adveco FUSION TW Hybrid Electric Water Heating Is Commercial Energy Saving Heating Product Of The Year

Building Products Index Ltd Water Heaters Leave a Comment

View the Advice entry on BPindex

Visit the Adveco website

Adveco’s FUSION TW, a packaged electric water heating system for commercial projects, was named winner of the Commercial Heating Product of the Year category at the 2025 Energy Saving Awards. The Energy Saving Awards celebrate the very best professionals, products and projects across the Plumbing, HVAC and Energy Management sectors, acknowledging the important work that has been achieved by manufacturers, installers, contractors, suppliers and organisations to reduce carbon emissions and become more energy efficient.

FUSION was conceived by the team at Adveco as a means of harnessing a hybrid approach to reduce energy demands and deliver a long-life low-carbon resolution for new build and gas-to-electric transition projects. It achieves this whilst avoiding costly oversizing and the need for bespoke system design, which raises costs and the impacts the feasibility of decarbonisation strategies.

The all-new FUSION-TW and TWplus packages take the existing sealed primary loop combination of ARDENT electric boiler and 750-litre ATST twin-coil cylinder and reimagines the system with the integration of the ADV-W series of air source heat pumps.

This provides a wider choice of compact, pre-charged R32 ASHPs for generation of system preheat by either a 10 – 16 kW single-phase ADVS-W ASHP or a 16-30 kW ADV-W in three-phase capacity.  With an A+++ ERP energy rating, and high SCOP with water outlet temperature 60° the ADV-W will maintain a consistent supply of hot water at up to 55° to pre-heat the FUSION system.

The TW-plus plus variants include either a 6 or 12 kW electric backup immersion for no single point of failure for assured delivery of hot water without downtime.

Greg Brushett, Sales Director, Adveco, said, “Winning at the 2025 Energy Saving Awards is another tremendous accolade for FUSION TW and reflects all the hard work the teams here at Adveco have invested in bringing a ground-breaking product to market. FUSION continues to change the way low-carbon water heating can be specified in commercial buildings. It allows for highly optimised applications which can be provided off-the-shelf in pre-sized, ready-to-go systems with a smaller footprint, that are easier to install, more efficient and cost-effective to purchase and operate. “

FUSION excels in the deployment of smart controls, maximising pre-heat input from the ADV-W series of heat pumps, capable of contributing as much as 70% of system heat requirements, and balancing this with the primary input of the ARDENT electric boiler so that the two heat sources blend harmoniously, offsetting as much direct electric demand as possible. FUSION’s new enhanced controls not only optimise the mixture of pre-heat from the heat pump, but they also manage the elements within the electric boiler and backup immersion. If this is not managed correctly by the controls, the two heat sources would act in contention, countering system efficiency and wasting energy. This also ensures the electric boiler is not required to work as hard to raise flow temperatures to the 65°C demanded by commercial applications, reducing maintenance demands and improving the longevity of the boiler.

Adveco has released new single- and three-phase control panels supporting both ADVS-W and ADV-W variant ASHP. Time control clock controls are built-in, as is thermal disinfection.  When connected to the BMS, disinfection and high-temperature pasteurisation functions can also be monitored when active, and a fault relay can be instigated. The new panels support connections for the LLH pump, lighting, socket, heater bar, secondary return pump and destratification pump output. With the inclusion of a GSM module, fault notifications can be enabled from the BMS or via text. The new controls also provide the option to prevent immersion activation when ASHP goes into fault to limit current.

Specification allows for the selection of a system based on nominal power output (kW), storage capacity (litres), continuous flow (litres/hour), instantaneous draw off capacity (litres) and peak draw off (litres). This offers 25 base variants of the TW, each supporting the addition of an incorporated backup electric immersion (TWplus).

When comparing TW and TWplus systems to equivalent direct electric DHW systems, offset energy use delivers carbon emission savings starting at 20.53% climbing to 47.75%. Across the entire range, we can see an average of 36.3% savings versus other direct electric systems.

When calculating the carbon emissions savings for FUSION TW, they become more notable when compared to gas-fired systems. Starting at 51.11% and climbing to as much as 67.86%.  Across the entire range, we can see an average of 60.8% savings versus the latest generation of gas water heater systems.

By embracing an indirect approach to water heating with a primary loop configuration FUSION is also able to provide assured operation which fully counters the effects of limescale in hard water areas, whilst its tough, stainless steel build is more than strong enough to prevent the corrosive action of soft water, making it a truly universal system no matter local water quality.

“Hybrid systems have the potential to be complex and come with greater capital expense, especially at a commercial scale,” Greg observes. “Adveco’s award-winning FUSION TW with ADV-W ASHP counters this with a far more compact monobloc form factor to lower entry costs for ASHP-based water heating and drive the uptake of sustainable systems in the UK.”

ADVECO FUSION TW/TWplus Key features

FUSION TW

  • High-quality ATST twin coil stainless steel vessel with mounting points & brackets
  • Available in 300 – 750 litre capacities
  • Cylinder pressure 10 bar as standard
  • 9, 12 or 24 kW electric boiler
  • 10, 12 or 16 kW single-phase air source heat pump
  • 16, 22 & 30 kW three-phase air source heat pump
  • Pre-built pipework (left or right)
  • FUSION Control Box
  • Compact space-saving form factor
  • 25 pre-sized variants from 19 to 52 kW

FUSION TWplus

  • 6 kW or 12 kW electric immersion
  • FUSION Control Box & GSM remote alerts
  • 25 pre-sized variants from 19 to 52 kW

https://adveco.co/products/water-heating/fusion-packaged-electric-water-heaters/

Adveco Introduces the Next Generation Of Packaged Electric Water Heating For Commercial Projects

Building Products Index Ltd Water Heaters Leave a Comment

View the Adveco entry on BPindex

Visit the Adveco website

Commercial hot water specialist Adveco introduces the next generation of FUSION electric water heating for commercial projects. FUSION-E is a tough, high-efficiency electric water heater. FUSION-T expands the system with the addition of a system-integrated heat pump and advanced controls. Both ranges can be further expanded with the addition of an electric immersion for greater reliance (FUSION-Eplus and FUSION-Tplus).

FUSION is the perfect response for commercial building projects with small to medium basin and sink-led hot water demands. Taller buildings with basement plant rooms and businesses that depend on 24/7 hot water provision for continuity of service all gain advantages from FUSION as well as reducing carbon emissions and controlling costs.

FUSION starts with all new specially designed single- (ATSI) or twin-coil (ATST) corrosion-resistant stainless steel high-pressure indirect cylinders. Offering capacities from 200 to 500 litres, the cylinders feature dedicated mounting points for Adveco’s 12 or 16 kW ARDENT electric boiler. By mounting the electric boiler directly to the cylinder FUSION is a more compact, space-saving option. Supplied with pre-built pipework the latest generation of FUSION is now faster and easier to install.

The electric boiler, with multiple immersions inside its sealed storage tank, provides automatically balanced usage to prolong system life and immediate resilience for the boiler. Used in a sealed ‘primary’ loop, the electric boiler heats the same water continuously effectively eliminating limescale issues typically found in electric systems used in hard water areas.

For the FUSION-T renewable variants, the 6 or 10 kW monobloc air-to-water FPi-32 heat pump (ASHP) is used as a source for system preheat. Contribution from the ASHP is maximised via the bespoke FUSION Control Box. These controls smartly balance the two heat sources, enabling the water in the cylinder to be heated in the most efficient way. As the electric boiler is not required to work as hard to raise flow temperatures to the 65°C demanded by commercial applications. Electrical demand on the boiler is reduced by as much as 30%, delivering operational savings and reducing carbon emissions by up to 71%.

The FUSION-T variants are perfect for organisations seeking to invest in a water heating application as part of a decarbonisation strategy without losing sight of higher operational costs associated with all-electric systems compared to equivalent gas-fired water heating.

Where hot water demands become a business-critical service, FUSION will also support the addition of an Adveco backup immersion providing additional resilience. Fitted into the front-facing clean-out access, the immersion ensures there is no single point of failure for assured service provision.

When only used as an emergency heating source, or during periods of unplanned excess demand, the inclusion of an electric immersion can be extremely advantageous. For FUSION systems incorporating the additional backup 6 or 12 kW immersion (FUSION-Eplus & FUSION-Tplus) controls are further extended to incorporate SMS output to advise building managers of a fault scenario and automated engagement of the immersion back-up to guarantee business-critical hot water supply.

For commercial organisations seeking a hot water system for new buildings faced with the regulatory changes on new gas connections or planning to move from existing gas-fired systems to electrical alternatives, FUSION provides an impressive range of choices. Whether cost, sustainability or business security are the driving factors for specification, FUSION offers a comprehensive response that can be quickly matched to the requirements of a project.

https://adveco.co/