Skip to content
BPindex — The Largest Building Products Directory in the UK

thermal break

Avoiding thermal bridging is critical with balcony design detailing

Building Products Index Ltd Thermal Breaks Leave a Comment

View the Schöck entry on BPindex

Visit the Schöck website

Image 1
Thermal images of a residential building with higher temperatures at the windows, doors and balconies

A thermal bridge is a localised area of the building envelope with significantly higher thermal conductivity than surrounding areas. Cantilevered balconies are the most critical thermal bridges and their presence results in a higher heat transfer out through the building and colder surface temperatures on the inside. The main consequences are higher energy consumption, non-compliance with Building Regulations and condensation. The latter leading not only to structural integrity problems, but the potentially serious occurrence of mould growth as well.

To meet Building Control requirements in England and Wales, it is necessary to demonstrate compliance with Building Regulations. The latest version of the Building Regulations Part L (2013, with 2016 amendments) and associated guidance document for residential construction Approved Document L1A (ADL1A) require that thermal bridging be included in the fabric heat loss calculations. However, despite the increasingly stringent standards for thermal performance and heat losses, many designers are still not fully aware of how significantly thermal bridges can compromise the value of the installed insulation.

Thermal performance and structural integrity

Image
Typical installation of structural thermal breaks involving concrete-to-concrete

The most effective way to minimise thermal bridging at cantilever balcony detailing is to incorporate a load-bearing structural thermal break such as the Isokorb from Schöck. This minimises the flow of thermal energy between the interior and exterior of a building, providing both structural integrity and ensuring that the balcony is thermally isolated. To work effectively over a long period thermal breaks require certain physical characteristics.  Thermal insulation with an optimum thickness for the particular application, load-bearing components and a combination of reinforced steel and stainless steel. A wide variety of thermal break solutions are available from Schöck for applications as diverse as: concrete-to-concrete; concrete-to-steel; steel-to-steel; renovation projects – and even Passive House.

Example of mould growth 1 - HROne consequence of thermal bridging is that surfaces can form condensation, causing visual deterioration and structural damage. However, an even bigger concern is mould growth. To identify areas where there is a risk of condensation and therefore mould growth, a ‘surface temperature factor’ (fRsi) should be used. It allows surveys under any thermal conditions and compares the temperature drop across the building fabric with the total temperature drop between the inside and outside air. Using the formula, the recommended value for offices and retail premises is equal to or greater than 0.5; and to ensure higher standards for occupants in residential buildings, equal to or greater than 0.75.

Passive House no longer a problem

Passive House uses highly energy-efficient building materials and preventing thermal bridging is essential.   Until relatively recently, balconies posed a construction challenge for Passive House design. Components penetrating the insulating outer shell of a thermally highly sensitive building demanded performance standards not achieveable by thermal break products on the market at the time. However, innovative product development means that high specification ‘Passive House certified’ structural thermal breaks from Schöck are now available for many applications.

Unrivalled performance from Schöck modular connectivity solution

Building Products Index Ltd Thermal Breaks, Thermal bridging Leave a Comment

View the Schöck entry on BPindex

Visit the Schöck website

EP 5 HRThe £2.3 billion Elephant Park regeneration project in the Elephant & Castle area of London  aims to create one of the most sustainable inner-city areas in Europe. There  are five phases, the third of which is currently live with eleven buildings divided into two plots – Park Central (North) and East Grove – providing 829 homes in total. Brick-finished midrise blocks to 11 and 12-storeys feature throughout and there are two main towers, one at 24-storey, the other 25-storey. Construction of the towers uses around 19,000 m2 of aluminium unitised façade panels supplied by FKN and Lindner, delivered complete with integrated sliding doors and openings ready for ventilation devices. There are hundreds of cantilever steel balconies throughout the project too, also pre-fabricated (including flooring and glazed balustrades) and supplied by Dearneside Fabrications Ltd.

Avoidance of  thermal bridging is critical

EP 6 HRWith steel having such high conductivity, the avoidance of  thermal bridging is critical throughout. Local heat loss is a major factor, resulting in more energy being required to maintain the building’s internal temperature. Also, low internal surface temperatures local to any thermal bridge can cause condensation, which is likely to result in structural integrity problems with absorbent materials.  Mould growth too is a possible risk and can cause asthma and allergies. The thermal performance at the connectivity points involving the balconies and the commercial façades therefore needed careful consideration. The Schöck Isokorb is universally recognised for its performance capability with balcony design detailing – but is less widely known for its ability to dramatically improve thermal performance involving façade engineering. On this project,  as the thermal zone sits outside the slab zone, the Schöck Isokorb T type S offers the ideal solution to both situations.

Unique and versatile

Type SThe versatile Schöck Isokorb T type S structural thermal break is the ideal connectivity solution for steel-to-steel applications. There are two variants, the T type S-N for tensile force and the T type S-V for transferring compression and shear forces. It is the only approved thermal break product that satisfies the load-bearing and thermal insulation requirements for steel design. Also, being a modular unit, it can be adapted to all profile sizes and load bearing capacity requirements – plus it can be used in both new construction and renovation projects.

Totally verifiable performance

In addition to steel-to-steel, the comprehensive Isokorb range also offers solutions for concrete-to-steel,  concrete-to-concrete – and even a maintenance free alternative to wrapped parapets. Products meet full compliance with the relevant UK building regulations, have NHBC approval, offer LABC Registration and the security of independent BBA Certification. The requirement that the temperature factor used to indicate condensation risk (fRSI) must be greater than, or equal to, 0.75 for residential buildings is also easily met by incorporating the Isokorb.