Skip to content
BPindex — The Largest Building Products Directory in the UK

cavity drainage system

Combination Waterproofing (Type A and C protection systems)

Building Products Index Ltd Cavity Drain Membranes, Membranes Leave a Comment

View the Delta Membranes entry on BPindex

Pre-Applied and Post-Applied Waterproofing – Delta Membranes

Type C, Cavity Drainage Waterproofing – Delta Membranes

Casestudies – Delta Membranes

Type A and Type C Waterproofing

Overview

The scope of this project was to offer a waterproofing solution to an early 19th century two storey, listed cottage sited in a conservation area of beautiful countryside in Scotland.

Delta Registered Installers, Structureseal Services Limited, were appointed to provide a guaranteed, cost-effective scheme that would comply with BS 8102:2022 (Protection of below ground structures against water ingress. Code of practice.).

For any structure below ground, either fully or partially, waterproofing is essential for protecting and preserving integrity.

BS 8102:2022 defines the three main methods of waterproofing protection as Type A (Barrier), Type B (Structurally Integral) and Type C (Drained).

A combination of two forms of waterproofing is preferred when designing a habitable space, often referred to as combination protection.   Where a combination of waterproofing protection is being used, the two systems should offer different performance characteristics to mitigate the risk of failure due to a common cause.

The specification and installation on the waterproofing protection will be influenced by the structure, ground conditions, along with the proposed use of the structure.  Continuity of the waterproofing protection is a further consideration when specifying a suitable scheme, along with compatibility of the different protection types which should be assessed in order to minimise the risks and negate the need for remedial measures.

Methodology

During design team meetings various revisions were made to the initially proposed waterproofing protection.  The structure required a new concrete slab which enabled the specification of Delta Amphibia, a Type A System and Delta Cavity Drainage Membranes, a Type C System.

Pre site inspections were carried out along with consultations with the customer, to ensure the waterproofing design not only meets BS 8102:2022 but also the client’s expectations.

The project was split into two phases:

Phase 1 – Installation of the Type A solution, Delta Amphibia.

Phase 2 – to install a secondary waterproofing system, such as the Delta Type C, Cavity Drainage System.

Phase 1

The 150mm ground slab was designed to the Structural Engineers details which included reinforcement where required.  The slab edge was reinforced to allow for a recess which would house the Delta Type C, perimeter drainage channel.

Prior to the concrete pour of the new structural slab, Delta Amphibia was specified as the primary waterproofing solution.  Delta Amphibia was installed vertically in a Type A, waterproofing application.

 

The unique properties of Delta Amphibia are achieved through four active layers – a watertight barrier, Reactive Core which allows Delta Amphibia to Self-Seal and Self-Heal in the event of accidental damage, an active barrier with the ability to Self-Seal at overlaps resisting lateral movement of water and a strong bonding layer.

Pre-applied bonded membranes are used to waterproof concrete in basements and below ground structures on the positive side (outside). They are installed before the reinforcement underneath a base slab and vertically on a soil retention system, or in a formwork.

Phase 2

Prior to the installation of the Type C System, to reduce the risk of free lime leaching out from the new concrete slab (during the curing process), Koster Polysil TG 500 was applied.

After ensuring the structure was water watertight Delta MS 500 cavity drained membrane was installed to the walls.

Cavity Drained Systems manage water penetration, Delta drainage channel, a water collection conduit designed to discharge water ingress was bedded into a preformed recess/gully at the floor/wall junction with incorporated inspection and maintenance points to comply with BS8102:2022.

Prior to the installation of Delta MS20 membrane, the basement slab was thoroughly flood tested.

All installed with great dealing and expertise.

Related Products

  • Delta Amphibia
  • Delta Amphibia Safety Tape
  • Delta Amphibia Lap Seal
  • Delta MS 500
  • Delta MS 20
  • Koster Polysil TG 500
  • Delta Channel and associated inspection ports

Case Study Results

Delivered on time and to budget!

Delta Registered Installers, Structureseal Services Limited were able to confidently recommend, design and install a comprehensive waterproofing solution that will protect this property from unwanted water ingress for the life cycle of the structure.

Delta Membranes Case Study – Fernroyd, Bowden

Building Products Index Ltd Waterproof Membranes, waterproofing Leave a Comment

View the Delta Membrane entry on BPi

Visit the Delta Membrane website

Problematic Residential Basement 2 copySPECIFICATION

NBS Specification J40 (Clause 290) Flexible Sheet Tanking/ Damp Proofing.

BS 8102:2009 Type C Drianed Protection.

SYSTEM COMPONENTS

  • Koster Polysil TG500 Anti Lime Coating/Surface Primer,
  • Delta MS 500,
  • Delta PT Delta, Problematic Residential Basement 5 copy
  • MS 20 Perimeter drainage channel
  • Delta Dual V3 Sump Pump

 Overview

The scope of the project was to renovate a problematic damp residential basement to create a habitable dry living space. The property is a magnificent Victorian detached residence, built around 1850.  The accommodation is extremely versatile and extends to around 5569 sq ft.  The property’s extensive basements consisted of: hallway, three chamber rooms, storeroom and wine cellar. The Victorian property in a sought after setting, in Altrincham, Manchester.

Problematic Residential Basement 3 copyAltrincham’s bedrock consists mainly of Keuper Waterstone (a type of sandstone). The project required sympathetic renovation, the property retaining a wealth of impressive original features including deep skirting boards, cornicing’s, mouldings, windows and shutters. Timberwise’s team were called upon to investigate the damp issues and to suggest remedial options which would incorporate BS 8102:2009.

All basements should be constructed (or retrofitted) to cope with groundwater levels up to the full retained height of the basement.  Structural waterproofing preserves the integrity of a structure whilst ensuring the usefulness of the building for present and future use.

Methodology

Problematic Residential Basement 4 copyWhere specified all basement waterproofing projects carried out by Timberwise are designed and installed in accordance with the current British Standard BS8102:2009 “The Code of Practice for Protection of Below Ground Structures against Water from the Ground”. The Delta Cavity Drain Membrane System was installed allowing water to continue to penetrate through the wall where the flow could be controlled within the air gap between the Cavity Problematic Residential basement 6 copyDrainage Membrane and the wall. Perimeter drainage channel manages the flow of the water through to a suitable drainage point or sump pump. Prior to installation of the Type C Cavity Drain Membrane, an application of Koster Polysil TG 500 anti-lime surface primer was applied to all new concrete surfaces. When new concrete forms there is a risk of excess free lime and mineral salts leaching out during the curing process. When a cavity drainage system is used in this type of application, a pre-treatment of the concrete is used to reduce the risk of free lime build up and blocking of the drainage cavity and perimeter channel.

Problematic Residential basement 7 copyVentilation Systems

The Waterproofing Design Specialist recommended that adequate ventilation and heating must be specified in the overall basement conversion in accordance with Part F of the Building Regulations.

Sump Pump System

A Delta PowerMaxx battery back-up and AlertMaxx2 Wi-Fi enabled alarm was installed to complement the system. A Delta Dual V3 sump pump system was installed to keep the area underneath the building dry and to prevent it from flooding. The sump pump’s job is to pump the water out of the pit and away from the building so the basement stays dry.

Case study review

Timberwise transformed what was a damp unused basement into a dry habitable living area. The customer was left fully satisfied with the end result. Having installed the system Timberwise provided the customer with a 10 year guarantee giving long term peace of mind.