Key Considerations When Specifying Ladders

Building Products Index Ltd Roof Hatches Leave a Comment

View the Bilco UK entry on BPindex

Visit the Bilco UK website

Tony Stevens, Technical Estimator at Bilco UK, outlines some of the key factors to be considered when specifying ladders for accessing a roof area.

Where is the ladder going to be used?

If the ladder is required to gain access to the roof and to be mounted externally it will require a safety cage and guard rail to enter the roof safely.

What is the ladder going to be used with?

You need to have a clear understanding of the type of access product the ladder is going to be used with.

For a small hatch, such as the Bilco E-50TB, which has internal dimensions of 915mm x 915mm, a fixed vertical ladder should be specified. A retractable ladder would not be recommended for the E-50TB as the ladder angle would hinder access when you get close to the hatch.

Dean Close School 023Where frequent access to the roof area is required for maintenance personnel, tools and equipment a companionway roof hatch, like the CS-50TB which is a larger elongated access hatch, is generally required.  In this instance a companionway ladder or a retractable ladder can be specified (the maximum size for companionway would be 2440mm and 1500mm for retractable).

The companionway ladder is a 75 degree angled, rigid ladder providing permanent access to the roof hatch.

Retractable ladders are ideal for use in areas, such as schools and hospitals, where the floor space must be kept clear. They can be mounted above a ceiling and be offered with additional vertical backboards with steps and a handrail. They can also be supplied with fire rating.

Where access is required to the roof area via a smoke ventilator, like the Bilco ESW-50REM, a retractable ladder is not an option.  The very nature of the mechanism of a retractable ladder would prevent the flow of smoke through the vent.  It would therefore be counterproductive to use a retractable ladder with a smoke vent, although we have seen this specified on more than one occasion!

The only recommended ladder for use with a smoke ventilator is a fixed vertical ladder, due to the small footprint of this type of ladder.

Ladder Height

Knowing the height of the floor to underside of roof access hatch that you wish to access may seem incredibly obvious, but you may be surprised by the number of ladders that are specified either too short or too long for the height required!

Roof Void Height

When specifying a retractable ladder it is essential that you know the height of the roof void – the space between the ceiling and the roof. This is to ensure the ladder box liner will fit inside the space once retracted.

What happens if you get the specification wrong?

If you specify a small hatch for use with either a companionway ladder or retractable ladder it will be difficult to access, so it will not be functional.

If you specify a large length hatch, it will be difficult to access from a fixed vertical ladder. The worker will have to overstretch to open and close the hatch, putting themselves into an unsafe position.

If you specify a retractable ladder with a smoke ventilator you will compromise the integrity of the smoke ventilator by blocking the flow of smoke.

To conclude, specifying ladders might seem like a straightforward aspect of a building project but the health and safety and functionality implications are far reaching.  Always ensure you specify the right type of ladder and hatch that will provide the safest and easiest access to the roof area.

If you need some help with specifying the right ladder to use for roof access please contact Tony – tony.stevens@access-360.co.uk.

New! Sliding Skylight Ventilators and Roof Hatches

Building Products Index Ltd Roofing, Rooflights 1 Comment

View the Bilco UK entry on BPi

Visit the Bilco UK website

Bilko image 1BILCO UK is pleased to introduce a new line of skylight products for smoke ventilator
and roof top access. The innovative design features a sliding cover that is electrically actuated for fast emergency response or access with just a push of a button. Click here for more information

Sliding Skylight Ventilator Vent

Bilko image 2Skylight ventilators feature an innovative sliding cover design that provides natural daylight and automatic smoke ventilation protection. This CE marked ventilator is readily available in a standard size and custom sizes can be specified.

Natural Smoke Ventilator Models: SKY-1M, SKY-SS

Standard Features and Benefits

  • CE marked skylight ventilators provide natural daylighting and smoke ventilation protection.
  • The unique sliding cover design does not require wind deflectors for smoke ventilation and features a rigid PVC frame with external metal profiles
  • Over-lapping design ensures complete weathertightness
  • The polyester upstand is fully insulated for energy efficiency
  • Low voltage actuator opens and closes the cover in a smooth and controlled motion.

 

Standard Sizes
Type Size (mm)  Overall Dimensions (mm) Weight (kg)
SKY-1M 1000 x 1500 1300 x 1800 170
SKY-SS Special*
* Fabricated to special size requirements. Consult Bilco for sizing.

Guide Specifications

  • Performance Characteristics: Dome has been tested for impact resistance to EN1873 Class SB1200. Operation of the cover shall be through a 24VDC battery backed control system that will open the cover to the fire open position within 60 seconds and be capable of closing the cover. Operation of the cover shall not be affected by temperature. Entire vent shall be weathertight. U-value 1.02 W/m2
  • Cover: Shall be a double-layer thermoformed polycarbonate dome assembled on a fully welded PVC frame, in which a double-layer security glass(classified 2(B)2 according to EN 12600:2004) shall be inserted. Cover shall have extruded EPDM rubber gasket to ensure a continuous seal when compressed in the front and in the back of the vent.
  • Cover Insulation: Not applicable.
  • Curb: Shall be 250 mm in height and of double-layer (internal and external) polyester resin reinforced with fiberglass. The curb shall be formed with a 150 mm flange with 9 mm holes provided for securing to the roof deck.
  • Curb Insulation: Shall be extruded polyurethane of 60mm thickness.
  • Operating Mechanism: 24VDC actuator
  • Finishes:
    • Factory finish shall be:
    • Polycarbonate: Clear Finish
    • Glass: Clear Finish
    • PVC Profiles: White
    • Metal Profiles: White Powder Coating
    • Upstand: White
  • Warranty: 10-year product warranty/ 2-year motor warranty. Contact BILCO for complete warranty details.