Skip to content
BPindex — The Largest Building Products Directory in the UK

Delta Membranes

Combination Waterproofing (Type A and C protection systems)

Building Products Index Ltd Cavity Drain Membranes, Membranes Leave a Comment

View the Delta Membranes entry on BPindex

Pre-Applied and Post-Applied Waterproofing – Delta Membranes

Type C, Cavity Drainage Waterproofing – Delta Membranes

Casestudies – Delta Membranes

Type A and Type C Waterproofing

Overview

The scope of this project was to offer a waterproofing solution to an early 19th century two storey, listed cottage sited in a conservation area of beautiful countryside in Scotland.

Delta Registered Installers, Structureseal Services Limited, were appointed to provide a guaranteed, cost-effective scheme that would comply with BS 8102:2022 (Protection of below ground structures against water ingress. Code of practice.).

For any structure below ground, either fully or partially, waterproofing is essential for protecting and preserving integrity.

BS 8102:2022 defines the three main methods of waterproofing protection as Type A (Barrier), Type B (Structurally Integral) and Type C (Drained).

A combination of two forms of waterproofing is preferred when designing a habitable space, often referred to as combination protection.   Where a combination of waterproofing protection is being used, the two systems should offer different performance characteristics to mitigate the risk of failure due to a common cause.

The specification and installation on the waterproofing protection will be influenced by the structure, ground conditions, along with the proposed use of the structure.  Continuity of the waterproofing protection is a further consideration when specifying a suitable scheme, along with compatibility of the different protection types which should be assessed in order to minimise the risks and negate the need for remedial measures.

Methodology

During design team meetings various revisions were made to the initially proposed waterproofing protection.  The structure required a new concrete slab which enabled the specification of Delta Amphibia, a Type A System and Delta Cavity Drainage Membranes, a Type C System.

Pre site inspections were carried out along with consultations with the customer, to ensure the waterproofing design not only meets BS 8102:2022 but also the client’s expectations.

The project was split into two phases:

Phase 1 – Installation of the Type A solution, Delta Amphibia.

Phase 2 – to install a secondary waterproofing system, such as the Delta Type C, Cavity Drainage System.

Phase 1

The 150mm ground slab was designed to the Structural Engineers details which included reinforcement where required.  The slab edge was reinforced to allow for a recess which would house the Delta Type C, perimeter drainage channel.

Prior to the concrete pour of the new structural slab, Delta Amphibia was specified as the primary waterproofing solution.  Delta Amphibia was installed vertically in a Type A, waterproofing application.

 

The unique properties of Delta Amphibia are achieved through four active layers – a watertight barrier, Reactive Core which allows Delta Amphibia to Self-Seal and Self-Heal in the event of accidental damage, an active barrier with the ability to Self-Seal at overlaps resisting lateral movement of water and a strong bonding layer.

Pre-applied bonded membranes are used to waterproof concrete in basements and below ground structures on the positive side (outside). They are installed before the reinforcement underneath a base slab and vertically on a soil retention system, or in a formwork.

Phase 2

Prior to the installation of the Type C System, to reduce the risk of free lime leaching out from the new concrete slab (during the curing process), Koster Polysil TG 500 was applied.

After ensuring the structure was water watertight Delta MS 500 cavity drained membrane was installed to the walls.

Cavity Drained Systems manage water penetration, Delta drainage channel, a water collection conduit designed to discharge water ingress was bedded into a preformed recess/gully at the floor/wall junction with incorporated inspection and maintenance points to comply with BS8102:2022.

Prior to the installation of Delta MS20 membrane, the basement slab was thoroughly flood tested.

All installed with great dealing and expertise.

Related Products

  • Delta Amphibia
  • Delta Amphibia Safety Tape
  • Delta Amphibia Lap Seal
  • Delta MS 500
  • Delta MS 20
  • Koster Polysil TG 500
  • Delta Channel and associated inspection ports

Case Study Results

Delivered on time and to budget!

Delta Registered Installers, Structureseal Services Limited were able to confidently recommend, design and install a comprehensive waterproofing solution that will protect this property from unwanted water ingress for the life cycle of the structure.

Custom Fabricating Services – site specific pump station requirements

View the Delta Membranes entry on BPindex

Pump Calculators – Delta Membranes

Package Pumps and Basement Drainage Systems – Delta Membranes

Casestudies – Delta Membranes

Pumping Systems fabricated to any size and/or configuration.

Delta Pumps and Basement Drainage Distribution Hub is home to Delta’s in-house fabrication team.  Our fabrication team not only fabricates the Delta 710, 910 and 800 Series chambers (used in structural waterproofing application) but also have capability and capacity to customize pumping systems to match any size and/or configuration to your specific site requirements.

All Delta pumping systems are fabricated from our dedicated Distribution Hub, a 3,500 sq. ft warehouse dedicated to pumping stations, packaged pump stations and basement drainage related products, from BBA Approved packaged pump stations, high water level alarms, control panels, battery backups to pipework and fittings, supporting the team’s ability to meet the growing demand for quality basement drainage items.

Along with fabricated pumping systems, Delta also offer loose package systems for new or existing RC sumps.

All Delta pumping systems are fabricated to included internal class E pipework, non-return valve(s) and guide rails, were applicable.

An extensive range of pumping stations can suit all types of application – Ground, surface, or foul water, single or twin discharge.

Our experienced inspection team thoroughly assurance check all Delta pumping stations before they leave the Distribution Hub to maintain consistent, expected quality levels of Delta pumping systems.

All Delta pumping systems are usually available on a next working day delivery.

Specification Services

Delta Pumps is the largest supplier of structural waterproofing application pumping systems.  Our products are designed and fabricated in-house by our specialists to ensure high standards.

Our in-house team of Specification Managers are always happy to help to ensure your pumping systems suit your project.   Simply complete a ‘Delta Pump Specification Sheet’ with your site requirements and let our teams do the rest. Delta’s Pumping System Specifications are not only site specific but also include technical details and design strategy whilst confirming to British Standards and Regulations.

To aid specification simply complete the information fields in our online pump calculator tools – https://www.deltamembranes.com/product-categories/pump-calculators/  – if  pumping requirements are outside of standard stock range then click submit and our specification team will be on hand to assist.

Retrofitting or new

Delta’s pumping systems are suitable for new and retrofitting projects.   We recommend consultation with a Delta Pumps Registered Servicing Provider/manufacturer with knowledge of pumps prior to replacing equipment to ensure the replacement pumping system operates in accordance with site specifics.

Always happy to help

Whatever the needs of your project, you can rely on Delta’s Technical Team to ensure you get the right advice, support, and practical help at exactly the right time its required.  Call us today on 01992 523 523 or email info@deltamembranes.com.

Waterproofing solution to a Basement close to a lake

Building Products Index Ltd Waterproof Membranes, waterproofing Leave a Comment

View the Delta Membranes entry on BPindex

Delta Membranes – Casestudies

Cavity Drained Protection (Type C Waterproofing)

 

Overview

Imagine waking up to the tranquil sound of rippling water and stepping outside to a stunning view of nature and wildlife.

The scope of the project was to provide a waterproofing solution to a luxurious lake side home.  The new build property will sit within close vicinity of a 400 ft lake.

The developer, a successful London property developer, approached Delta to undertake the waterproofing design.  The developer, having previously had a prosperous relationship with Delta, once again sought Delta’s expertise in this project success.

The property itself being new build, was constructed from a Type B, waterproof reinforced concrete to provide a first form of waterproofing protection, with both Type C, and Type A, waterproofing solutions being incorporated to the structure to provide two forms of protection.

It is essential for the success of any project involving below ground structures that strategies for dealing with all external sources of groundwater, surface/flood water are considered from the very earliest stages of the planning and design process.  Particularly when a structure is sited within metres of a body of water.

When it comes to residential, commercial or any structure below ground, waterproofing is a critical component within the construction process for protecting and preserving a building.

Methodology

Applying all principles of waterproofing design (BS 8102:2022 Protection of below ground structures against water ingress. Code of Practice.), this project required a strategic, deliverable, approach.  Following site inspections and desk top studies, consideration was given to the need for combined protection, the need for continuity in the solution, the form and feasibility of repair of the systems, the weather/environment effect on systems, and the durability of the systems and performance over time.

With no one-size-fits-all when it comes to waterproofing design.  The property would sit in a high-water table, with de-watering required throughout the excavation process to temporarily lower groundwater levels, to allow stable conditions below the natural groundwater level.

The basement once constructed will sit 2 metres below the water level of the lake.  With sump pumps being installed at an even lower level (approximately 4m below the surface of the lake).

Prior to the installation of the Type C system, coved fillets were created at critical floor/wall junctions. Koster Polysil TG 500 was used to prevent the leaching of free lime in the new concrete.  Koster Polysil TG 500 if often used in combination with Delta cavity drainage membranes and basement drainage systems.

Delta MS 500 was securely fixed to the internal walls using Delta’s specialist fixing plugs, with Delta MS20 installed to floors.

Below the floor membrane perimeter drainage channels were sited within the rebates allowing for suitable drainage of any future water ingress and this being diverted to suitable discharge point (on this occasion a mechanical pump system).

Part of this ‘controlled system’ is basement drainage.  Any water ingress which penetrates the basement, is directed into perimeter drainage channels which this then efficiently disperse to a sump pump station.  Once collected in the sump pump chamber, the water is then pumped to a suitable evacuation point.

The need to service and maintain the drainage elements of type C waterproofing systems is paramount to long-term success.  Inspection ports were included in the perimeter channel with a groundwater sump pump located to give easy access for periodic servicing.

A Foul water pump station was incorporated into the design, to discharge foul water from the basement’s bathroom facilities.

After the Type C System was installed the all-important integrity testing was undertaken to exercise the waterproofing system in worst case scenario.

Working in partnership with the developer, Delta designed a bespoke Type A waterproofing approach to the light-well of the property.  Light wells being open element of the structure will require a suitable waterproofing approach.  Basement light-wells are earth retaining and are subject to lateral penetration from groundwater.  Lateral penetration is a caused when the external ground level is higher than the building, so water and moisture is able to penetrate the walls.  Light-wells can also be affected by rainwater, with heavy rain, light-wells can fill up, with the potential for water to cascade into the basement.  By waterproofing the envelope of the structure, this avoids potential risk.  Incorporating Koster NB 1 to the light-well was a simple solution.  Koster NB 1 with its ability to cope with both negative and positive pressure ensured that the accommodation areas would be kept dry, while the surface water pump station would manage any excess rainwater, to ensure the area is permanently protected and kept dry.

Incorporating a sump pump system for managing external surface water from light-wells is a great cost-effective solution.

Products Used

  • Delta MS 500
  • Delta MS 20
  • Koster NB 1 Grey
  • Koster SB Bonding
  • Koster Repair Mortar
  • Koster Polysil TG 500

Case Study Results

This unique project required a complex waterproofing design.  A key element to the success of this project has been the partnership between manufacturer/waterproofing designer and developer.  The developer has embraced Delta’s technical approach to fully understand Delta’s design principles, products, and compliance with specific standards for quality, reliability, and performance.

We wish the developer and his family lots of love and happiness in their new home.

Delta Amphibia, Reactive Core Liner

Building Products Index Ltd Waterproof Membranes Leave a Comment

View the Delta Membranes entry on BPindex

Introduction to Delta Amphibia

Delta Amphibia product page

BBA Certificates

Delta Amphibia is a unique Self-Healing/Repairing, Self-Sealing, fully bonded Type A waterproofing membrane, utilising its advanced Reactive Core technology, Delta Amphibia will not only Self-Repair in the event of accidental puncture and Self-Heal, but will also Self-Seal.

Delta Amphibia is a pre- and post-applied waterproofing membrane which can be installed horizontally and vertically in a Type A waterproofing application.

The unique properties of Delta Amphibia are achieved through four active layers – a watertight barrier, Reactive Core which allows Delta Amphibia to Self-Seal and Self-Heal in the event of accidental damage, an active barrier with the ability to Self-Seal at overlaps resisting lateral movement of water and a strong bonding layer.

Pre-applied bonded membranes are used to waterproof concrete in basements and below ground structures on the positive side (outside). They are installed before the reinforcement underneath a base slab and vertically on a soil retention system, or in a formwork.

The unique Self-Repairing function of Delta Amphibia protects structures from water and moisture permeability in the event of accidental puncture.  Delta Amphibia’s unique Self-Repairing function is activated in the event of Delta Amphibia being damaged.

Delta Amphibia’s Active Core offers continuous protection at overlaps.  Delta Amphibia has excellent crack-bridging capabilities at places where cracks may occur. When pre-applied (before the concrete pour), the wet concrete is absorbed into Delta Amphibia’s fleece Bond Layer, integrally bonding Delta Amphibia to concrete.

Benefits of Delta Amphibia

  • Active protection for watertight waterproofing
    • Self-Repairing
    • Self-Sealing
    • Self-Healing
    • Self-Fastening
  • Vertical or Horizontal application
  • Absolute impermeability with no side seepage of water
  • Immediate mechanical protection, self-repairing also on accidental puncture
  • High resistance to hydraulic load
  • High flexibility and capacity to bridge cracks
  • Full mechanical bond to concrete
  • Extremely flexible – Resistant to movement and fissures in substrates

Delta Amphibia satisfies all grades of waterproofing in accordance with BS 8102:2022, Table 2 as Type A, Barrier Protection System in accordance with section 8, Type A (Barrier) Protection – Sub Section 8.2.4, Active Core Liners and Table 3, Waterproofing Barriers.

Delta Membrane Systems Limited is a manufacturer and provider of specialist structural waterproofing solutions, covering Type A, Type B, and Type C waterproofing, combination waterproofing, damp proofing, basement drainage, flood resilience and ground gas protection.

Whatever the needs of your project, you can rely on Delta’s Technical Team to ensure you get the right advice, support, and practical help at exactly the right time its required.  Call us today on 01992 523 523 or email info@deltamembranes.com.

 

Delta Launch New Product Brochure

Building Products Index Ltd Membranes Leave a Comment

View the Delta Membranes entry on BPindex

Delta Brochures – Delta Membranes

Product – Delta Membranes

Application – Delta Membranes

We are excited to announce the release of the new Delta Product Catalogue. Delta’s new 135-page catalogue, is packed full of products, featuring helpful product information which includes handy estimating guides and coverage rates.

Designed to be easy-to-use in an eco-friendly, A5 pocket size.  Offering high quality visuals all organised into easy to navigate colour coded sections (from Ground Gas Protection to Concrete Repair) ensuring customers can quickly and easily source and order the right product for their project.

Our introduction section explains more about Delta including our core services in supporting correct project specification and application.  From waterproofing Types: A, B to C, with over two hundred products listed, this catalogue will help you specify a robust, long-lasting, and efficient waterproofing approach.

Highlights of the Delta catalogue include:

  • Dedicated about us section, incorporating a company overview and services offered
  • Extended product information on our range of specialist membranes, such as the Delta MS 500 Fire Retardant Membrane
  • Handy charts (coverage rates and measurements) included for Surveyors, Specifiers, and Site Personnel

Despite the global challenges which have affected every business, Delta managed to launch four new innovative product ranges expanding our portfolio:

Delta MS 500 Fire Retardant

The Delta MS 500 Fire Retardant is the only Fire Retardant, Type C Membrane with BBA accreditation available in the UK market, and the only Type C waterproofing membrane with a B-S2, d0 Euroclass fire rating (EN 13501-1:2018).

 Delta Amphibia

Delta Amphibia is a pre- and post- applied fully bonded waterproofing membrane with reactive core, this hydro-reactive, self-healing, self-sealing multi-layer waterproofing system which can be applied on vertical and horizontal areas of new construction.

Delta Roof Guard

Delta Roof Guard waterproofing systems are certified Broof (t4), complying with the regulations on resistance and safety on flat roofs, mitigating fire risk.

Delta Roof Guard cold applied liquid waterproofing systems are engineered to provide a fast curing, flexible, elastomeric solution for roofs, podium decks, terraces, balconies, walkways, and car parks.

Koster BDM

Koster BDM crystallizing, chloride free sealing agent for the integral waterproofing of concrete elements. Koster BDM combines all three important characteristics for integral waterproofing. It crystallizes, blocks capillaries, and makes the concrete water repellent.  This reduces the water absorbency of concrete, increases its compressive strength and resistance against chemical attack.  It is free of corrosive ingredients and is non-sensitive to mechanical damage to the surface.

We hope you will find our new catalogue informative and convenient.

Request your copy today by emailing orders@deltamembranes.com

Delta Amphibia Pre & Post Applied Membrane Awarded BBA

Building Products Index Ltd Waterproof Membranes Leave a Comment

PrintView the Delta Membranes entry on BPindex

Visit the Delta Membranes website

View the Delta Membranes brochures

Visit the Delta Membranes video suite

BBA Award for Delta Amphibia, Pre- Post Applied Membrane

DCIM/100MEDIA/DJI_0040.JPG

We are proud to announce that our Amphibia, a pre- and post- applied fully bonded waterproofing membrane with reactive core, this hydro-reactive, self-healing, self-sealing multi-layer waterproofing system which can be applied on vertical and horizontal areas of new construction has been awarded BBA Certification, rubberstamping Delta’s rigorous approach to product specification and assessment.
Agrément Certificates ensure products and systems that have passed a series of comprehensive assessments – including laboratory tests, on-site evaluations, quality management checks and inspections of production.

Perfec_Bind_Amphibia_BrochureCertification includes:

•  factors relating to compliance with Building Regulations where applicable
•  factors relating to additional non-regulatory information where applicable
•  independently verified technical specification
•  assessment criteria and technical investigations
•  design considerations
•  installation guidance
•  regular surveillance of production
•  formal three-yearly review.

BBA certification is a mark of quality, safety and reliability and is recognised by building control, government departments, architects, local authorities, specifiers, and industry insurers.

Delta Amphibia – Pre- Post Applied Waterproofing Membranes

Perfec_Bind_Amphibia_InstallKey factors assessed included:

  • Resistance to water and water vapour — the system provides an effective barrier to the passage of water under hydrostatic pressure and water vapour from the ground.
  • Resistance to mechanical damage — the system will accept the limited foot traffic and loads associated with installation.
  • Durability — under normal service conditions and when suitably protected, the system will provide an effective barrier to the transmission of liquid water and water vapour for the design service life of the structure in which it is incorporated.

NHBC Standards 2018

Amphibia rotolo + ScatolaIn the opinion of the BBA, Delta Amphibia, if installed, used, and maintained in accordance with this Certificate, can satisfy or contribute to satisfying the relevant requirements in relation to NHBC Standards, Chapter 5.4 Waterproofing of basements and other below ground structures.

Where Grade 3 (BS 8102:2022, Table 2) waterproofing protection is required, and the below ground wall retains more than 600 mm (measured from the top of the retained ground to the lowest finished floor level).

In the opinion of the BBA, the system is suitable for use on existing structures when installed and used in accordance with this Certificate and NHBC Standards for Conversions and Renovations, taking account of other relevant guidance within this document on the suitability of the substrate to receive the system, and where necessary, the relevant Chapters of NHBC Standards.

BS 8102:2022

Delta Amphibia satisfies all grades of waterproofing in accordance with BS 8102:2022, Table 2 as Type A, Barrier Protection System in accordance with section 8, Type A (Barrier) Protection – Sub Section 8.2.4, Active Core Liners and Table 3, Waterproofing Barriers.

CE marking

The Certificate holder has taken the responsibility of CE marking the system, in accordance with harmonised European Standard BS EN 15814:2011.
For more information on our Amphibia Membranes visit our website at www.deltamembranes.com.

BS 8102:2022 – Structural Waterproofing and Ground Gas Protection

Building Products Index Ltd Gas Membranes, Membranes Leave a Comment

View the delta Membranes entry on BPindex

Visit the Delta Membranes website

Technical Drawings – Ground Gas Protection Systems – Delta Membranes

Ground Gas Protection Systems – Delta Membranes

Gas Protection Systems – Delta Membranes

MemTech LGBKevin Dodds, Delta’s Manging Director, shares some thoughts on structural waterproofing and ground gas protection approaches.

With much anticipation, BSI launch BS8102:2022 Protection of Below Ground Structures Against Water Ingress. Code of practice.  Within the update is recognition of combining both structural waterproofing and ground gas protection.

Prior to the launch of BS8102:2022, both BS8102:2009 and BS8485:2015+A1:2019 were intertwined, however BS8102:2022 provides further and greater clarification on design approaches.

Awareness and a better understanding of the potential impact of ground gas is being recognised more and more by both industry professions and homeowners alike.  Ground gases aren’t particularly something new, however newer technologies for dealing with ground gases are.  With innovative new products, and approaches to design it’s possible to provide both a robust, continuous waterproof and gas proof design.

LGB Detailing 9#Ground gases either occur naturally or through human activity which impacts on environmental factors.  From Radon to Volatile Organic Compounds (VOCs), the impact of ground gases on occupiers of a structure built on a contaminated site are substantial.  From health issues to toxicity, ground gases should be approached with caution.

A desktop study is the first part of the site investigation process, depending on the risks present, these findings will contribute to determining the overall protection systems chosen.

If a site has been identified with ground gas or hydrocarbon contamination it will be given a Characteristic Situation Score.  The Characteristic Situation Score is defined according to how severe the gas flow and gas concentration from the ground/soil is.

All sites which have been characterised with a gas situation score will require a gas protection system and where identified a waterproof protection barrier.

Ground Gas Membranes - Titan being installed on siteGround gas protection is a barrier that prevents hazardous gases and contaminants from the underlying soils entering a structure. A well-designed system can also perform the function of a damp-proof membrane, assisting in preventing the ingress of moisture into the structure.

Waterproof protection is the prevention of water ingress into a structure.  A well-designed system may also perform the function of a ground gas protection system (product selection pending).

Evaluation of groundwater conditions, risk assessment and options for drainage outside the structure should always be considered and included in the overall design.

A Waterproofing Design Specialist will be able to interpret the requirements of BS8102:2022 and BS8485:2015+A1:2019 along with other legislative documents to produce a waterproofing design which incorporates both a waterproof and gas proof protection system.

A key element of this design approach is a continuous solution.  When we use the term “continuous”, we are referring to the design approach, which should include the whole structure (from detailing to any opening), ensuring the entire structure is protected.

We are always Happy to Help

Do you have questions about a project, product, or application?  In an ever-changing industry where reduced risk and higher quality is required, you need a waterproofing design partner that is proactive and dedicated to help you keep up with new technologies and solutions to ensure your projects thrive. Whatever the needs of your business, you can rely on the #DeltaTeam to ensure you get the right advice, support, and practical help at exactly the right time to keep you ahead of the competition.

Contact: 01992 523 523

Email: info@deltamembranes.com

Website: www.deltamembranes.com

What is cold applied liquid roofing/waterproofing?

Building Products Index Ltd Membranes, Waterproof Membranes Leave a Comment

View the Delta Membranes entry on BPindex

Visit the Delta Membranes website

View the Delta Membranes case studies

View Delta Membranes interactive video guides

What is cold liquid applied roofing waterproofingAs the name implies, cold applied liquid roofing/waterproofing is the use of a liquid waterproofing system without the requirement of heat.

Waterproofing roofs (whether it’s a flat roof or podium deck) is one of the most important structural requirements of any building. A watertight roof performs a vital function in protecting a structure.

When water starts to stand on a roof, not only can it lead to structural damages, it can also reduce the roof’s lifespan.  In the roofing industry, ponding water refers to water that has stood flat on a roof for longer than 2 days following precipitation.  Ponded water on roofs can also be a breeding ground for micro-organisms and other bacteria. This can be particularly problematic where the roof is protecting a hospital or school.  Flat roofs are a regular feature on public and commercial properties such as schools, hospitals, leisure centres, warehouses and factories.

Cold Liquid Applied WaterproofingLiquid waterproofing systems or cold liquid roofing are a great cost-effective method for waterproofing both new and existing roofs.

Simple to install and long-lasting, there is little doubt that the introduction of liquid waterproofing has been one of the most innovating advances in the industry.

Cold liquid waterproofing is simple and ready to use, at once forming an effective barrier to water and humidity.

Due to cold liquid roofing’s easy to apply nature, it is suitable to a wide variety of uses.  Applied with a simple brush, it easily allows reach to the almost inaccessible of areas, meaning that critical areas for the overall quality of the waterproofing are continuously and completely covered, guaranteeing the total protection for surfaces.

Benefits

Roof Guard Group ShotsCold liquid applied roofing is significantly faster, safer and less labour intensive to apply than conventional roofing materials.

Cold applied roofing, requires no torches, burners, or other heating equipment during application, posing no fire risks.  A cold applied liquid waterproofer cures to form an elastomeric waterproof membrane. Practically bonding directly to a substrate, providing a seamless, UV-stable continuous system, able to contour any roof shape for intricate detailing.

Why cold applied liquid systems?

Cold applied liquid waterproofing systems are engineered to supply a fast curing, long-lasting, flexible, elastomeric solution.

Other benefits include:

  • Excellent adhesion to all kinds of surfaces
  • Chemical resistant
  • High resistance to extreme temperatures
  • Completely seamless waterproofing
  • No heat or special equipment needed

Delta provides a comprehensive Technical Support Service for architects, designers, engineers, specifiers and contractors, with guidance on product selection, design advice and installation guidance. Your building is one of your most valuable assets which needs to be protected to ensure its long-term durability. You need to be confident that you have made the right choice for your investment from the very start.

Remedial Basement Waterproofing to commercial structure

Building Products Index Ltd Cavity Drain Membranes, Membranes Leave a Comment

View the Delta Membranes entry on BPindex

Visit the Delta Membranes website

Technical Drawings (Structural Waterproofing) – Delta Membranes

Product – Delta Membranes

Application – Delta Membranes

Overview
Remedial Basement Waterproofing to commercial structure 16Waterproofing design is a key and critical component for successful construction of below ground structures.  Whether it’s a completely new build or making smaller changes to an existing property, waterproofing design should never be overlooked.

Waterproofing might account for just a small fraction of a building’s total cost, but waterproofing defects can result in catastrophic consequences.  When waterproofing fails, the implications are significant.

Delta’s MD, Kevin Dodds was approached to offer advice and guidance on a failed waterproofing system.

The existing structure had an impressive 5-level basement which houses: kitchens, food storage and food preparation areas, spa, plant rooms and accommodation.  Near to a large river, the site sited well within the water table.  The original waterproofing system was based on the secant piled walls and a block wall internally to provide a basic drained protection system with drainage holes at various points to drain to various levels.

Over time, the third floor had become completely saturated with all levels of the basement experiencing water ingress in varying levels from damp patches to significant “jets” of water and flows of water through the secant piles.

With remediation waterproofing design strategies, it may take some time to specify a suitable system.  It is important that investigations are thoroughly carried out by individuals with the capability of diagnosing the defect, assessing the extent of that defect, and recommending a suitable corrective measure.

Methodology

Remedial Basement Waterproofing to commercial structure 13Following preliminary site inspections, discussions were held on remedial options, methodology for remedial works and cost.  During site observations significant water was sitting behind the corbel.  This water could be entering the structure either: directly through the piles, from the floor above or from the joint between the soffit and piles or a combination of all three.

When designing a robust waterproofing remediation approach, attention to detail is critical.

 

Balancing costs with quality, method suitability testing was carried out on trial areas.  A combination of resin injections and curtain injection were proposed prior to the installation of a Type C cavity drain membrane system to facilitate performance levels.  Alternative combinations were suggested on two trial areas.

Firstly, the secant piles were exposed and thoroughly cleaned to remove dirt, salts, and loose particles.  Whilst slow flowing leaks and drips could be sealed with resin injections alone, any fast-flowing water ingress was stopped in advance of injection works with the use of Koster KD Blitz 2.

Koster 2 IN 1 was injected into the corbel area with Koster IN 7 being injected into the vertical joints between the piles.

It was observed following inspections, over a 5-week period, that the corbel area was dry.  Delta’s MD, Kevin Dodds suggested a further monitoring period, or until two periods of heavy rain to assess performance levels.

Phase 1

Remedial Basement Waterproofing to commercial structure 5Following trials and analysis of approach, Kevin suggested the use of Koster G4 Gel as a curtain injection to areas identified after exposure works to each area, in combination with Koster 2 IN 1 injection resin to the corbel detail.  Each area would be injected and monitored for a period of 3 weeks prior to the installation of the Delta Type C cavity drain system.  To achieve a full belts and bridges approach, further tweaks to the design would be incorporated as and when different degrees of water ingress was encountered or where concrete to the scant piles were particularly poor, this included increasing levels of the G4 salt accelerant to the G4 Gel to increase speed of reaction without compromising the ability to spread to create the “waterproof curtain” behind the piles in the area.

As the entire sub-structure was susceptible to hydrostatic pressure, the best approach to the 5-levels would be to work one level at a time, working downwards in sequence.

Phase 2

The principles of the Type C, cavity drain system were straightforward and typical of a multi-level basement.  Additional design considerations were incorporated for detailing the corbel on which mid floor slabs required a careful approach.  Kevin suggested increasing the number of downward drainage weepholes from upper to lower levels for continued access for maintenance, along with discharge points.

In addition to this approach, compartmentalisation of the cavity drainage system was required for fire safety.

Products used

  • Koster IN 7
  • Koster 2 IN 1
  • Koster G4 Gel
  • Koster KD2 Blitz
  • Koster Waterstop
  • Koster NB 1
  • Koster Repair Mortar Plus
  • Koster KB Flex 200
  • Delta MS 500
  • Delta MS 20
  • Delta Drainage Channel
  • Dual V3 Pumps, Alertmaxx 2 High level alarms

Case Study Results

When it comes to remedial waterproofing, a great waterproofing outcome is with waterproofing experts.  This project has been one of partnering, from our partners at Koster UK to the main contractor, sub-contractor, and Delta Registered Installers Prestec Ltd who expertly installed the remedial solution.

Partnering in this project has been one of open communication, commitment of shared goals and mutual trust.

The timeframe for these remedial works were over a – year period, with works to levels 2 and 3 having already been completed.  The overall strategy, continuous trials, site monitoring and the ability to adapt the overall waterproofing design throughout the project have enabled completion of the works to date to an incredibly high standard with all parties confident with the positive and collaborative approach.

Technical Waterproofing Consultants can assist with the right products for the right results, whilst using the correct methodology.

Specifying Fire Retardant Structural Waterproofing Systems

Building Products Index Ltd Membranes Leave a Comment

View the Delta Membranes entry on BPindexDELTA MEMBRANES LOGOS revA

Visit the Delta Membranes website

Paying attention to waterproofing products which offer protection in event of fire is not the norm.  We hardly think of water management and fire in the same thought, however the benefits of doing so are not quite as crazy as it sounds.

The demand for sustainable, cost efficient building methods and materials is constantly increasing, as is the demand for safer building materials.  The waterproofing sector should embrace and support the goal of creating healthy and safe living environments throughout the lifecycle of products.

There are many different design challenges experienced when designing a suitable, maintainable and capable waterproofing system.  From existing basements to multi-level basements – basements which will encompass high water tables at some stage during their service life.

8 copyWith Delta MS 500 Fire Retardant membrane it is now possible to specify a Type C, Cavity Drainage Membrane that offers not only protection from water or vapour ingress but also protection in the event of fire.

Video Stills-17 copy Video Stills-03 copy

 

 

 

 

 

 

Comparison of Class E Type C Cavity Drainage Membrane and Delta MS 500 Fire Retardant with naked flame

The Delta Fire Retardant range has been manufactured with DELTASAFE, a new innovative fire-retardant property which enables our MS 500 membrane to achieve a Euroclass rating of B-S2, d0 in accordance with EN 13501-1:2018 meaning it is now possible to specify a Type C Cavity Drainage Membrane that meets building requirements of today, but also that of tomorrow, without having to radically alter specifications.

Video Stills-12 copy Video Stills-06 copy

 

 

 

 

 

 

Comparison of Membrane Fixing Plug and Delta Ultra Fix Fire Retardant Fixing plug with naked flame.

A Type C Cavity Drainage System is a maintainable basement waterproofing solution suitable for new-build basements, refurbishment and retrofit projects. The Type C System comprises of a Cavity Drain Membrane, Drainage system, Submersible Package Pump and Control System. This type of system is designed to combat water ingress and can be used to habitable grades 1-3 in according to BS 8102:2009.

The Delta Fire Retardant Type C Cavity Drainage System is the safest form of waterproofing system available, offering complete protection from water or water vapour and fire retardant protection.

Our Design and Build Philosophy is quality driven, working with architects and trades alike, putting at the forefront construction considerations to ensure buildability, functionality, and maintainability. The result of this single approach is a consistent, complete, and quality design that is hard to equal.

The success of any project is highly influenced by the team tasked with delivering it, let our Technical Team assist in you in your successful project.   We don’t wait for problems to arise and then work to solve them; we identify them in advance and solve them before they become a problem.

Whatever the needs of your project, you can rely on Delta’s Technical Team to ensure you get the right advice, support and practical help at exactly the right time to keep you ahead of the competition.  Call us today on 01992 523 523 or email info@deltamembranes.com.